CESMD |
Information for Strong-Motion Station |
Indio - 4-story Gov Office Bldg [Demolished] |
CGS - CSMIP Station 12493 |
Earthquakes recorded by this station |
Latitude | 33.7138 N |
Longitude | 116.2220 W |
Elevation (m) | -4 |
Site Geology | Deep alluvium |
Vs30 (m/sec) | 282 (inferred) |
Site Class | D |
Remarks/Notes | Site information sources |
No. of Stories above/below ground | 4/1 |
Plan Shape | Rectangular |
Base Dimensions | 90' x 210' |
Typical Floor Dimensions | Same as base dimensions |
Design Date | 1966 |
Instrumentation | 1985. 10 accelerometers, on 3 levels in the building. 3 accelerometers at a reference free-field site. |
Vertical Load Carrying System | Reinforced concrete slab floors and roof supported by reinforced concrete frames. |
Lateral Force Resisting System | Moment resisting reinforced concrete frame (distributed elements) with concrete shear walls @ stairs and elevators. |
Foundation Type | Piles. |
Remarks | -- |