CESMD
Information for Strong-Motion Station
Indio - 4-story Gov Office Bldg [Demolished]
CGS - CSMIP Station 12493
Earthquakes recorded by this station
 
(Station Photograph - click to enlarge)(Sensor Layout - click to see PDF File)
   
Latitude 33.7138 N
Longitude 116.2220 W
Elevation (m) -4
Site Geology Deep alluvium
Vs30 (m/sec) 282 (inferred)
Site Class D
Remarks/Notes Site information sources
 
No. of Stories above/below ground4/1
Plan ShapeRectangular
Base Dimensions90' x 210'
Typical Floor DimensionsSame as base dimensions
Design Date1966
Instrumentation1985. 10 accelerometers, on 3 levels in the building. 3 accelerometers at a reference free-field site.
 
Vertical Load Carrying SystemReinforced concrete slab floors and roof supported by reinforced concrete frames.
Lateral Force Resisting SystemMoment resisting reinforced concrete frame (distributed elements) with concrete shear walls @ stairs and elevators.
Foundation TypePiles.
Remarks--