CESMD |
Information for Strong-Motion Station |
Ontario - 5-story Hospital |
CGS - CSMIP Station 23416 |
Earthquakes recorded by this station |
Latitude | 34.0322 N |
Longitude | 117.6082 W |
Elevation (m) | 250 |
Site Geology | Alluvium |
Vs30 (m/sec) | 386 (measured) |
Site Class | C |
Remarks/Notes | Site information sources |
No. of Stories above/below ground | 5/partial |
Plan Shape | Rectangular (with irregularities) |
Base Dimensions | 396 ft x 291 ft |
Typical Floor Dimensions | 396 ft x 291 ft |
Design Date | 2006 |
Instrumentation | 2010, 15 accelerometers on 5 levels and 3 relative displacement sensors on 3 levels, and 3 free-field. |
Vertical Load Carrying System | Concrete over steel deck supported by steel beams and columns. |
Lateral Force Resisting System | Steel buckling restrained braced frames distributed in both directions, and concrete shear walls at basement level. |
Foundation Type | Continuous concrete footings at perimeter and isolated concrete footings at interior steel columns. |
Remarks | The building design conforms to the 2001 CBC. Funding for instrumentation was provided by the owner as required by OSHPD. CSMIP provided assistance in instrumentation. |